import atexit
|
|
|
|
import functools
|
|
|
|
import logging
|
|
|
|
import os
|
|
|
|
import signal
|
|
|
|
import sys
|
|
|
|
|
|
|
|
import gevent.lock
|
|
|
|
from monotonic import monotonic
|
|
|
|
import prometheus_client as prom
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
def timed(name=None,
|
|
|
|
buckets=[10.**x for x in range(-9, 5)], normalized_buckets=None,
|
|
|
|
normalize=None,
|
|
|
|
**labels
|
|
|
|
):
|
|
|
|
"""Decorator that instruments wrapped function to record real, user and system time
|
|
|
|
as a prometheus histogram.
|
|
|
|
|
|
|
|
Metrics are recorded as NAME_latency, NAME_cputime{type=user} and NAME_cputime{type=system}
|
|
|
|
respectively. User and system time are process-wide (which means they'll be largely meaningless
|
|
|
|
if you're using gevent and the wrapped function blocks) and do not include subprocesses.
|
|
|
|
|
|
|
|
NAME defaults to the wrapped function's name.
|
|
|
|
|
|
|
|
Any labels passed in are included. Given label values may be callable, in which case
|
|
|
|
they are passed the input and result from the wrapped function and should return a label value.
|
|
|
|
Otherwise the given label value is used directly. All label values are automatically str()'d.
|
|
|
|
|
|
|
|
In addition, the "error" label is automatically included, and set to "" if no exception
|
|
|
|
occurs, or the name of the exception type if one does.
|
|
|
|
|
|
|
|
The normalize argument, if given, causes the creation of a second set of metrics
|
|
|
|
NAME_normalized_latency, etc. The normalize argument should be a callable which
|
|
|
|
takes the input and result of the wrapped function and returns a normalization factor.
|
|
|
|
All normalized metrics divide the observed times by this factor.
|
|
|
|
The intent is to allow a function which is expected to take longer given a larger input
|
|
|
|
to be timed on a per-input basis.
|
|
|
|
As a special case, when normalize returns 0 or None, normalized metrics are not updated.
|
|
|
|
|
|
|
|
The buckets kwarg is as per prometheus_client.Histogram. The default is a conservative
|
|
|
|
but sparse range covering nanoseconds to hours.
|
|
|
|
The normalized_buckets kwarg applies to the normalized metrics, and defaults to the same
|
|
|
|
as buckets.
|
|
|
|
|
|
|
|
All callables that take inputs and result take them as follows: The first arg is the result,
|
|
|
|
followed by *args and **kwargs as per the function's inputs.
|
|
|
|
If the wrapped function errored, result is None.
|
|
|
|
To simplify error handling in these functions, any errors are taken to mean None,
|
|
|
|
and None is interpreted as '' for label values.
|
|
|
|
|
|
|
|
Contrived Example:
|
|
|
|
@timed("scanner",
|
|
|
|
# constant label
|
|
|
|
foo="my example label",
|
|
|
|
# label dependent on input
|
|
|
|
all=lambda results, predicate, list, find_all=False: find_all,
|
|
|
|
# label dependent on output
|
|
|
|
found=lambda results, *a, **k: len(found) > 0,
|
|
|
|
# normalized on input
|
|
|
|
normalize=lambda results, predicate, list, **k: len(list),
|
|
|
|
)
|
|
|
|
def scanner(predicate, list, find_all=False):
|
|
|
|
results = []
|
|
|
|
for item in list:
|
|
|
|
if predicate(item):
|
|
|
|
results.append(item)
|
|
|
|
if not find_all:
|
|
|
|
break
|
|
|
|
return results
|
|
|
|
"""
|
|
|
|
|
|
|
|
if normalized_buckets is None:
|
|
|
|
normalized_buckets = buckets
|
|
|
|
# convert constant (non-callable) values into callables for consistency
|
|
|
|
labels = {
|
|
|
|
# there's a pyflakes bug here suggesting that v is undefined, but it isn't
|
|
|
|
k: v if callable(v) else (lambda *a, **k: v)
|
|
|
|
for k, v in labels.items()
|
|
|
|
}
|
|
|
|
|
|
|
|
def _timed(fn):
|
|
|
|
# can't safely assign to name inside closure, we use a new _name variable instead
|
|
|
|
_name = fn.__name__ if name is None else name
|
|
|
|
|
|
|
|
latency = prom.Histogram(
|
|
|
|
"{}_latency".format(_name),
|
|
|
|
"Wall clock time taken to execute {}".format(_name),
|
|
|
|
labels.keys() + ['error'],
|
|
|
|
buckets=buckets,
|
|
|
|
)
|
|
|
|
cputime = prom.Histogram(
|
|
|
|
"{}_cputime".format(_name),
|
|
|
|
"Process-wide consumed CPU time during execution of {}".format(_name),
|
|
|
|
labels.keys() + ['error', 'type'],
|
|
|
|
buckets=buckets,
|
|
|
|
)
|
|
|
|
if normalize:
|
|
|
|
normal_latency = prom.Histogram(
|
|
|
|
"{}_latency_normalized".format(_name),
|
|
|
|
"Wall clock time taken to execute {} per unit of work".format(_name),
|
|
|
|
labels.keys() + ['error'],
|
|
|
|
buckets=normalized_buckets,
|
|
|
|
)
|
|
|
|
normal_cputime = prom.Histogram(
|
|
|
|
"{}_cputime_normalized".format(_name),
|
|
|
|
"Process-wide consumed CPU time during execution of {} per unit of work".format(_name),
|
|
|
|
labels.keys() + ['error', 'type'],
|
|
|
|
buckets=normalized_buckets,
|
|
|
|
)
|
|
|
|
|
|
|
|
@functools.wraps(fn)
|
|
|
|
def wrapper(*args, **kwargs):
|
|
|
|
start_monotonic = monotonic()
|
|
|
|
start_user, start_sys, _, _, _ = os.times()
|
|
|
|
|
|
|
|
try:
|
|
|
|
ret = fn(*args, **kwargs)
|
|
|
|
except Exception:
|
|
|
|
ret = None
|
|
|
|
error_type, error, tb = sys.exc_info()
|
|
|
|
else:
|
|
|
|
error = None
|
|
|
|
|
|
|
|
end_monotonic = monotonic()
|
|
|
|
end_user, end_sys, _, _, _ = os.times()
|
|
|
|
wall_time = end_monotonic - start_monotonic
|
|
|
|
user_time = end_user - start_user
|
|
|
|
sys_time = end_sys - start_sys
|
|
|
|
|
|
|
|
label_values = {}
|
|
|
|
for k, v in labels.items():
|
|
|
|
try:
|
|
|
|
value = v(ret, *args, **kwargs)
|
|
|
|
except Exception:
|
|
|
|
value = None
|
|
|
|
label_values[k] = '' if value is None else str(value)
|
|
|
|
label_values.update(error='' if error is None else type(error).__name__)
|
|
|
|
|
|
|
|
latency.labels(**label_values).observe(wall_time)
|
|
|
|
cputime.labels(type='user', **label_values).observe(user_time)
|
|
|
|
cputime.labels(type='system', **label_values).observe(sys_time)
|
|
|
|
if normalize:
|
|
|
|
try:
|
|
|
|
factor = normalize(ret, *args, **kwargs)
|
|
|
|
except Exception:
|
|
|
|
factor = None
|
|
|
|
if factor is not None and factor > 0:
|
|
|
|
normal_latency.labels(**label_values).observe(wall_time / factor)
|
|
|
|
normal_cputime.labels(type='user', **label_values).observe(user_time / factor)
|
|
|
|
normal_cputime.labels(type='system', **label_values).observe(sys_time / factor)
|
|
|
|
|
|
|
|
if error is None:
|
|
|
|
return ret
|
|
|
|
raise error_type, error, tb # re-raise error with original traceback
|
|
|
|
|
|
|
|
return wrapper
|
|
|
|
|
|
|
|
return _timed
|
|
|
|
|
|
|
|
|
|
|
|
log_count = prom.Counter("log_count", "Count of messages logged", ["level", "module", "function"])
|
|
|
|
|
|
|
|
class PromLogCountsHandler(logging.Handler):
|
|
|
|
"""A logging handler that records a count of logs by level, module and function."""
|
|
|
|
def emit(self, record):
|
|
|
|
log_count.labels(record.levelname, record.module, record.funcName).inc()
|
|
|
|
|
|
|
|
@classmethod
|
|
|
|
def install(cls):
|
|
|
|
root_logger = logging.getLogger()
|
|
|
|
root_logger.addHandler(cls())
|
|
|
|
|
|
|
|
|
|
|
|
def install_stacksampler(interval=0.005):
|
|
|
|
"""Samples the stack every INTERVAL seconds of user time.
|
|
|
|
We could use user+sys time but that leads to interrupting syscalls,
|
|
|
|
which may affect performance, and we care mostly about user time anyway.
|
|
|
|
"""
|
|
|
|
# Note we only start each next timer once the previous timer signal has been processed.
|
|
|
|
# There are two reasons for this:
|
|
|
|
# 1. Avoid handling a signal while already handling a signal, however unlikely,
|
|
|
|
# as this could lead to a deadlock due to locking inside prometheus_client.
|
|
|
|
# 2. Avoid biasing the results by effectively not including the time taken to do the actual
|
|
|
|
# stack sampling.
|
|
|
|
|
|
|
|
flamegraph = prom.Counter(
|
|
|
|
"flamegraph",
|
|
|
|
"Approx time consumed by each unique stack trace seen by sampling the stack",
|
|
|
|
["stack"]
|
|
|
|
)
|
|
|
|
# HACK: It's possible to deadlock if we handle a signal during a prometheus collect
|
|
|
|
# operation that locks our flamegraph metric. We then try to take the lock when recording the
|
|
|
|
# metric, but can't.
|
|
|
|
# As a hacky work around, we replace the lock with a dummy lock that doesn't actually lock anything.
|
|
|
|
# This is reasonably safe. We know that only one copy of sample() will ever run at once,
|
|
|
|
# and nothing else but sample() and collect() will touch the metric, leaving two possibilities:
|
|
|
|
# 1. Multiple collects happen at once: Safe. They only do read operations.
|
|
|
|
# 2. A sample during a collect: Safe. The collect only does a copy inside the locked part,
|
|
|
|
# so it just means it'll either get a copy with the new label set, or without it.
|
|
|
|
# This presumes the implementation doesn't change to make that different, however.
|
|
|
|
flamegraph._lock = gevent.lock.DummySemaphore()
|
|
|
|
# There is also a lock we need to bypass on the actual counter values themselves.
|
|
|
|
# Since they get created dynamically, this means we need to replace the lock function
|
|
|
|
# that is used to create them.
|
|
|
|
# This unfortunately means we go without locking for all metrics, not just this one,
|
|
|
|
# however this is safe because we are using gevent, not threading. The lock is only
|
|
|
|
# used to make incrementing/decrementing the counter thread-safe, which is not a concern
|
|
|
|
# under gevent since there are no switch points under the lock.
|
|
|
|
import prometheus_client.values
|
|
|
|
prometheus_client.values.Lock = gevent.lock.DummySemaphore
|
|
|
|
|
|
|
|
|
|
|
|
def sample(signum, frame):
|
|
|
|
stack = []
|
|
|
|
while frame is not None:
|
|
|
|
stack.append(frame)
|
|
|
|
frame = frame.f_back
|
|
|
|
# format each frame as FUNCTION(MODULE)
|
|
|
|
stack = ";".join(
|
|
|
|
"{}({})".format(frame.f_code.co_name, frame.f_globals.get('__name__'))
|
|
|
|
for frame in stack[::-1]
|
|
|
|
)
|
|
|
|
# increase counter by interval, so final units are in seconds
|
|
|
|
flamegraph.labels(stack).inc(interval)
|
|
|
|
# schedule the next signal
|
|
|
|
signal.setitimer(signal.ITIMER_VIRTUAL, interval)
|
|
|
|
|
|
|
|
def cancel():
|
|
|
|
signal.setitimer(signal.ITIMER_VIRTUAL, 0)
|
|
|
|
atexit.register(cancel)
|
|
|
|
|
|
|
|
signal.signal(signal.SIGVTALRM, sample)
|
|
|
|
# deliver the first signal in INTERVAL seconds
|
|
|
|
signal.setitimer(signal.ITIMER_VIRTUAL, interval)
|
|
|
|
|
|
|
|
|
|
|
|
|